1-35kV 1.5-800mm2 Sectional Area Electric Power Cable

1-35kV 1.5-800mm2 Sectional Area Electric Power Cable
Product Detailed

power cable
1~Section:1.5-800 for 1kV,25-630 for 3-35kV
2~Standard:GB/T12706,IEC60502,ASTM,BS
3~ISO9001,ISO14001,OHSAS18001

1-35kV 1.5-800mm2 Sectional Area Electric Power Cable

  

It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction,mines, metallurgy  petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable

 

1.Constructions&Drawings

 

1.Conductor: Solid or stranded Aluminum/copper

2.Insulation: Cross-linked polyethylene/XLPE (or PVC)

3.Circuit Identication: The insulation shall be red, black.

4.Filler:Polypropylene lament with lapped binding tape.

5.Inner Sheath: Polyvinyl chloride (black)

6.Armor: Galvanized steel wire/steel tape/Unarmored/Aluminum wire

7.Core-covering: Binding tape

8.Outer Sheath: Polyvinyl chloride(black)

9.Application: For use in ducts, trays and direct burial in ground.

 

2. Standards

GB/T12706.1-2002<<Rated Voltage 1KV(Um=1.2KV) to 35KV(Um=40.5kv) Power Cable with extruded insulation and accessories Part 1:Rated Voltage 1KV(Um=1.2KV) and 3KV(Um=3.6KV) Cables>>

GB/T12706.2-2002<<Rated Voltage 1KV(Um=1.2KV) to 35KV(Um=40.5kv) Power Cable with extruded insulation and accessories Part 2:Rated Voltage 6KV(Um=7.2KV) and 30KV(Um=36KV) Cables>>

GB/T12706.3-2002<<Rated Voltage 1KV(Um=1.2KV) to 35KV(Um=40.5kv) Power Cable with extruded insulation and accessories Part 3:Rated Voltage 35KV(Um=40.5KV) Cables>>

We can also manufacture according to IEC60502, BS, DIN and ASTM etc standards upon customers' requirements.

 

3. Service Characteristic

a.the long-time working temperature of cable should not be higher than 90°C.

b.When core is in short-circuit (max 5s) the temperature should not exceed 250°C.

c.While installation the ambient temperature should not be lower than 0°C.

d.The bending radius should not be less than:(D is outer diameter cable)

(1) single-core cables:unarmored 20D;armored 15D.

(2) much-core cables:unarmored 15D;armored 12D.

 

4. Type, Designation and Applications

Type

Description

Application

Cu Core

Al Core

YJV

ZR-YJV

YJLV

ZR-YJLV

Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable

Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force.

YJV22

ZR-YJV22

YJLV22

ZR-YJLV22

Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable

Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force.

YJV32

ZR-YJV32

YJLV32

ZR-YJLV32

Cu(Al)Core, XLPE Insulated, Thin Steel Wire Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Thin Steel Wire Armored and PVC Sheathed flame- retardant Power Cable

Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force.

YJV42

ZR-YJV42

YJLV42

ZR-YJLV42

Cu(Al)Core, XLPE Insulated, Thick Steel Wire Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Thick Steel Wire Armored and PVC Sheathed flame- retardant Power Cable

Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force.

 

5. Specifications

1KV XLPE INSULATED POWER CABLE

Model 

Core number

Nominal cross section

mm2

Copper 

aluminium

YJV YJY

YJV22 YJV23


YJLV YJLY
YJLV22 YJLV23

1

1.5~800
2.5~800
10~800

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

2

1.5~300
2.5~300
2.5~300
10~300

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

3

1.5~400
2.5~400
2.5~400
10~400

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

4

1.5~400
2.5~400
2.5~400
10~400

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

3+1

1.5~400
4.0~400
4.0~400
10~400

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

5

1.5~400
2.5~400
2.5~400
10~400

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

4+1

1.5~400
4.0~400
4.0~400
10~400

YJV YJY

YJV22 YJV23
YJV32 YJV33


YJLV YJLY
YJLV22 YJLV23
YJLV32 YJLV33

3+2

1.5~400
4.0~400
4.0~400
10~400

 

 

 



Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.